20+ Years Team Experience
Over 20 years of combined fire sprinkler inspection experience, field-tested on commercial and industrial buildings across Connecticut.
NFPA 25 Compliance
Royal Fire Protection inspects and tests fire sprinkler systems, fire pumps and standpipes for Connecticut commercial and industrial buildings — annual NFPA 25 inspection, quarterly testing and five-year internal inspection.
Royal Fire Protection performs annual NFPA 25 inspection and testing for Connecticut commercial and industrial buildings, with licensed inspectors, detailed written reports and fire-marshal-ready documentation.
Annual NFPA 25 inspection by a licensed Connecticut contractor is required for every commercial sprinkler system — visual inspection of accessible heads, control-valve verification, gauge checks and alarm-valve testing.
Inspection and testing aren’t the same thing: inspection is visual, testing is operational, and NFPA 25 requires both at different intervals. Heads are inspected annually for damage, corrosion or obstruction; flow tests run quarterly to annually depending on the system.
Annual fire pump testing at three points on the pump curve, as required by NFPA 25, with controller verification, jockey-pump testing and complete performance documentation for your building records.
Diesel pumps also get fuel-system inspection, oil changes, battery testing and coolant service; electric pumps get controller testing and generator coordination — all inside the annual scope.
Standpipe inspection covers hose-valve testing, pressure-reducing-valve verification and the five-year internal inspection of hose valves required by NFPA 25.
The five-year internal inspection opens critical valve components to assess wear and corrosion; owners often schedule it alongside the annual visit to cut trips and coordinate corrections.
Why Choose Royal
Don't Take the Risk
Protect your people and your property with a code-compliant fire protection system, installed by a licensed Connecticut contractor.
Our Work
Why Us
Over 20 years of combined fire sprinkler inspection experience, field-tested on commercial and industrial buildings across Connecticut.
NFPA 25 reports with photos of deficiencies, specific corrective actions and fire-marshal-ready documentation delivered fast.
Our reports pass Connecticut fire-marshal review the first time, backed by local relationships with building departments.
A report format built for major insurance carriers — used by owners for policy renewal and claims.
FAQ